Process Sensor FD-Q20C Keyence
Process Sensor FD-Q20C Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

FD-Q20C Keyence Process Sensor

Manufacturer

Keyence

Country

Japan

Name

FD-Q20C

Type

Process Sensor

Description

anklemmbarer Durchflusssensor ½“ (max. 60 L/min) bzw. ¾” (max. 100 L/min)

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications FD-Q20C

If you are looking for Keyence FD-Q20C , catch up with FAMAGA, the world's major provider of industrial equipment. Our company has existed for more than ten years - these are cycles of experience, which are illustrated in the quality of goods and special attention to each orderer. We esteem everyone, who engaged with us - therefore, our regular consumers receive the most desirable purchase forms and discounts on the machine made streamlined equipment market. At this time, there are more than 4000 such customers, and we constantly make new agreements. More than 600 transactions are made per day, because FAMAGA operates all over the earth . A well-shaped logistics series and a partnership network guide us to ship our goods anywhere in the globe with no delay without disreputing product quality.

A special source of dignity for FAMAGA is its staff members, each of whom contributes to our work. We accept into our team only specialists, who already have experience in the range of industrial equipment.

All outcomes from FAMAGA are verified - we are responsible for the result of our work. At the moment, more than 10 million units of products have been shipped, and this quantity is amounting every day. We are glad that consumers choose FAMAGA again and again, and we are glad to make more advanced and technologically modern industrial equipment so as to stay on the top.

To get some advice or place an order, call us by phone or send a message to the online chat on our official website. You can also forward a list of the desirable equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features FD-Q20C

Sensor Main Unit 15A/20A Type
Model FD-Q20C
Supported pipe diameter 1/2' (15 A), o18 to o23 (mm) 3/4' (20 A), o23 to o28 (mm)
Supported pipe materials Metal pipe/Resin pipe*1
Supported fluids Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1
Supported fluid temperature 0 to 85°C (No freezing on the pipe surface)*2
Maximum rated flow 1/2' (15 A): 60 L/min 3/4' (20 A): 100 L/min
Zero cut flow rate 2.5 L/min (Default)*3
Display method Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator
Display update cycle Approx. 3 Hz
Display resolution 0.1/ 1 (Default : 0.1) (L/min)
Response time 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s
Repeatability 0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4 (Specific to selected response time))
Hysteresis Variable
Integrated flow unit display 0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)
Integrated flow data storage cycle Save to memory every 10 seconds
Memory backup EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)
Power I/O connector M12 4-pin connector
Input/Output (Selectable) Output (ch.1/ch.2) Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5
Analogue output (ch.1/ch.2) 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 ? or less*5
External input (ch.2) Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), short-circuit current 1.5 mA or less, input time 20 ms or more*5
Power source Power supply voltage 20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS
Current consumption 100 mA or less (Load current excluded)*6
Protection circuit Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection
Environmental resistance Enclosure rating IP65/IP67 (IEC60529)
Ambient temperature -10 to +60 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Sensor main unit PPS/PES/PBT/SUS303/SUS304/SUSXM7
Sensor surface Rubber
Mounting bracket SUS304/PA/SUSXM7
Weight Approx. 400 g (including mounting bracket)
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) *2 Contact KEYENCE when the temperature of the pipe is greater than 85°C *3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate. *4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range. *5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO) *6 When including the loads, please add 200 mA to this value.