We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
FD-Q50C
Type
Process Sensor
Description
Sensor Main Unit 40A/50A Type
Stock availability:
On request
If you are questing Keyence FD-Q50C , call FAMAGA, the world's key provider of streamlined equipment. Our company has progressed for more than ten years - these are years of experience, which are described in the quality of spare parts and personalseparate attention to each purchaser. We value everyone, who joined with us - therefore, our regular clients accept the most flexible purchase conditions and discounts on the machine made streamlined equipment market. At this moment, there are more than 4000 such clients, and we constantly sign new agreements. More than 600 affairs are settled per day, because FAMAGA supplies all over the earth Germany, United Kingdom, Myanmar, Ukraine, Chile, Chad, Seychelles, Namibia, Saudi Arabia, Georgia, Algeria, Hungary, Papua New Guinea, Slovakia, Israel, Dominica, Norway, Canada, Austria, Belize, Libya, Benin, Liechtenstein, Czech Republic, Montenegro, Jamaica, India, Turkey, Zambia, Qatar, Bosnia and Herzegovina, Kuwait, Niger, Cameroon, Mali, United States, Tonga, Estonia, Equatorial Guinea, Sudan, Tanzania, Poland. A well-built logistics chains and a partnership network let us to dispatch our items anywhere in the globe immediately without discrediting product quality.
A specific source of good name for FAMAGA is its employees, each of whom contributes to our work. We propose into our team only experts, who already have experience in the range of industrial equipment.
All spare parts from FAMAGA are assured - we are responsible for the result of our work. At the moment, more than 10 million units of products have been provided, and this quantity is ascending every day. We are glad that purchasers choose FAMAGA again and again, and we are happy to make more advanced and technologically modern industrial equipment so as to stay on the top.
To ask a question or place an order, get in touch with us or write a message to the online chat on our official website. You can also forward a list of the desirable equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Model | FD-Q50C | |
Supported pipe diameter | 1 1/2' (40 A), o44 to o52 (mm) 2' (50 A), o52 to o64 (mm) | |
Supported pipe materials | Metal pipe/Resin pipe*1 | |
Supported fluids | Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1 | |
Supported fluid temperature | 0 to 85°C (No freezing on the pipe surface)*2 | |
Maximum rated flow | 1 1/2' (40 A): 400 L/min 2' (50 A): 500 L/min | |
Zero cut flow rate | 25 L/min (Default)*3 | |
Display method | Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator | |
Display update cycle | Approx. 3 Hz | |
Display resolution | 0.1/ 1 (Default :1) (L/min) | |
Response time | 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s | |
Repeatability | 0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4 (Specific to selected response time)) | |
Hysteresis | Variable | |
Integrated flow unit display | 1/ 10/ 100/ 1000/ 10000 (Default : 1) (L) | |
Integrated flow data storage cycle | Save to memory every 10 seconds | |
Memory backup | EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) | |
Power I/O connector | M12 4-pin connector | |
Input/Output (Selectable) | Output (ch.1/ch.2) | Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5 |
Analogue output (ch.1/ch.2) | 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 ? or less*5 | |
External input (ch.2) | Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), short-circuit current 1.5 mA or less, input time 20 ms or more*5 | |
Power source | Power supply voltage | 20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS |
Current consumption | 130 mA or less (Load current excluded)*6 | |
Protection circuit | Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection | |
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) |
Ambient temperature | -10 to +60 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | |
Material | Sensor main unit | PPS/PES/PBT/SUS303/SUS304/SUSXM7 |
Sensor surface | Rubber | |
Mounting bracket | SUS304/PA/POM/SUSXM7 | |
Weight | Approx. 640 g (including mounting bracket) | |
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) *2 Contact KEYENCE when the temperature of the pipe is greater than 85°C *3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate. *4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range. *5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO) *6 When including the loads, please add 200 mA to this value. |