We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
FD-Q32C
Type
Process Sensor
Description
anklemmbarer Durchflusssensor 1“ (max. 200 L/min) bzw. 1 ¼“ (max. 300 L/min) 90261021000 CHINA
Stock availability:
On request
If you are questing Keyence FD-Q32C , reach FAMAGA, the world's major provider of factory-made equipment. Our company has existed for more than ten years - these are ages of experience, which are symbolized in the quality of products and private attention to each customer. We understand everyone, who engaged with us - hence, our regular customers get the most helpful purchase conditions and discounts on the industrial equipment market. Now, there are more than 4000 such consumers, and we constantly form new agreements. More than 650 purchases are terminated per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Dominican Republic, Vietnam, Guatemala, Romania, Rwanda, Samoa, Singapore, Burundi, East Timor, Egypt, Tajikistan, Ireland, Mauritania, New Zealand, Panama, Zimbabwe, Seychelles, Fiji, Poland, Greece, The Bahamas, South Korea, Afghanistan, Jordan, Togo, Indonesia, Serbia, Malta, Haiti, Senegal, United States, The Gambia, Finland, Mali, Philippines, Kiribati, Syria, Dominica, Cyprus, Hungary. A well-elaborated logistics bond and a partnership network assist us to dispatch our products anywhere in the world on-time without compromising product quality.
A particular source of honor for FAMAGA is its staff members, each of whom contributes to our work. We invite into our team only experts, who already have experience in the sphere of industrial equipment.
All outputs from FAMAGA are affirmed - we are responsible for the outcome of our work. Nowadays, more than 10 million units of products have been shipped, and this quantity is rising every day. We are pleased that consumers choose FAMAGA again and again, and we are happy to make more developed and technologically developed industrial equipment so as to stay on the top.
To request or place an order, contact us or write a message to the online chat on our site. You can also forward a list of the desirable equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
Model | FD-Q32C | |
Supported pipe diameter | 1' (25 A), o28 to o37 (mm) 1 1/4' (32 A), o37 to o44 (mm) | |
Supported pipe materials | Metal pipe/Resin pipe*1 | |
Supported fluids | Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1 | |
Supported fluid temperature | 0 to 85°C (No freezing on the pipe surface)*2 | |
Maximum rated flow | 1' (25 A): 200 L/min 1 1/4' (32 A): 300 L/min | |
Zero cut flow rate | 5 L/min (Default)*3 | |
Display method | Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator | |
Display update cycle | Approx. 3 Hz | |
Display resolution | 0.1/ 1 (Default :1) (L/min) | |
Response time | 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s | |
Repeatability | 0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4 (Specific to selected response time)) | |
Hysteresis | Variable | |
Integrated flow unit display | 1/ 10/ 100/ 1000/ 10000 (Default : 1) (L) | |
Integrated flow data storage cycle | Save to memory every 10 seconds | |
Memory backup | EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) | |
Power I/O connector | M12 4-pin connector | |
Input/Output (Selectable) | Output (ch.1/ch.2) | Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5 |
Analogue output (ch.1/ch.2) | 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 ? or less*5 | |
External input (ch.2) | Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), short-circuit current 1.5 mA or less, input time 20 ms or more*5 | |
Power source | Power supply voltage | 20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS |
Current consumption | 130 mA or less (Load current excluded)*6 | |
Protection circuit | Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection | |
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) |
Ambient temperature | -10 to +60 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | |
Material | Sensor main unit | PPS/PES/PBT/SUS303/SUS304/SUSXM7 |
Sensor surface | Rubber | |
Mounting bracket | SUS304/PA/POM/SUSXM7 | |
Weight | Approx. 530 g (including mounting bracket) | |
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) *2 Contact KEYENCE when the temperature of the pipe is greater than 85°C *3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate. *4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range. *5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO) *6 When including the loads, please add 200 mA to this value. |